Observation Equipment
-
View all
-
Sightglasses
-
Sight Flow Indicators
-
Lights for Sightglasses
-
Liquid Level Gauges
-
Armored Level Gauges
Process Equipment
-
View All
-
Manways
-
Spray Balls
-
Valves - Ball and Butterfly
-
SMS Fittings
-
DIN Fittings
Washdown Equipment
-
View All
-
Steam and Water Mixing Station
-
Thermostatically Controlled Mixing Station
-
Hot and Cold Water Mixing Station
-
Accessories
Miscellaneous Equipment
-
View All
-
Gauge Glass and Gaskets
OBSERVATION EQUIPMENT - LIGHTS for SIGHTGLASSES
Observation Equipments
>
Lights for Sightglasses
>
Lighting Units
Model:
KEL
Hazardous area light fitting
KEL
5dH
KEL
5 deH
KEL
10 dH
KEL
10 deH
KEL
20 dH
KEL
20 deH
KEL
50deH
Nominal rating
(VA)
5
5
10
10
20
20
50
Terminal voltage
(V)
12, 24, 36, 42, 115, 220, 240
12, 24, 36, 42, 115, 220, 240
12, 24, 36, 42, 115, 220, 240
12, 24, 42, 115, 220, 240
12, 24, 42, 115, 220, 240
12, 24, 42, 115, 220, 240
12, 24
Transformer built-in
not with terminal voltage of (V)
12
12
12
12
12,24
12,24
Secondary voltage of build-in-transformer
(V)
12
12
12
12
12
12
Bulb
Halogen
Halogen
Halogen
Halogen
Halogen
Halogen
Halogen
Socket
G4
G4
G4
G4
G4
G4
GY 6.35
Lateral junction box
Weight with lateral junction box (kg)*
with transfo
2.15
2.15
2.15
without transfo
1.65
1.65
1.65
1.65
Weight without lateral junction box (kg)*
with transfo
2.25
2.25
2.25
without transfo
1.75
1.75
1.75
Ignition protection type to EN 50018/50019 VDE 0170/0171
EEx d
EEx de
EEx d
EEx de
EExd
EEx de
EEx de
Explosion group (All explosion classes)
IIC
IIC
IIC
IIC
IIC
IIC
IIC
Temperature class
T6
T6
T4
T4
T4
T4
T3
Certificate of conformity Nr. Ex-86/
2125
2125
2125
2125
2125
2125
2125
*Only light fitting. Fixations 'W' 0.03Kg, 'Sch' 0.16kg.
The models in the following table are specially suitable and recommended for use on pipeline sight flow indicators.
Hazardous area light fitting
KEL 10d
KEL
10 de
KEL 6-10 d
KEL
6-10 de
KEL
15 d
KEL
15de
KEL
25 de
Nominal rating
(VA)
10
10
6-10
6-10
15
15
25
Terminal voltage
(V)
24
24
220-260
220-260
220
220
220
Socket
E 14
E 14
E 14
E 14
E 14
E 14
E 14
Lateral junction box
Weight with lateral junction box (kg)*
1.65
1.65
1.65
1.65
Weight without lateral junction box (kg)*
1.75
1.75
1.75
Ignition protection type to EN 50018/50019 VDE 0170/0171
EEx d
EEx de
EEx d
EEx de
EEx d
EEx de
EEx de
Explosion group (All explosion classes)
II C
II C
II C
II C
II C
II C
II C
Temperature class
without transfo
T6
T6
T6
T6
T6
T6
T5
Certificate of conformity Nr. Ex-86/
with transfo
2087
2087
2087
2087
2087
2087
2087
*Only light fitting. Fixations 'W' 0.03Kg, 'Sch' 0.16kg.
Registration
|
Login
|
Check Shipment
|
Trade Shows
|
Sitemap
|
Links
357 Spook Rock Road
Suffern, NY 10901
Tel: (845)368-3600
Fax: (845)368-3040
Contact Us