Pressure and Temperature Ratings:
ARCHON Reflex Gauges Model RL |
| |
| Size Gauge |
100 ° F |
200 ° F |
300 ° F |
400 ° F |
500 ° F |
600 ° F |
| 1 x 1 |
2400 |
2320 |
2240 |
2150 |
2000 |
1780 |
| 1 x 2 |
2325 |
2250 |
2170 |
2080 |
1940 |
1720 |
| 1 x 3 |
2250 |
2180 |
2100 |
2020 |
1880 |
1670 |
| 1 x 4 |
2175 |
2100 |
2020 |
1940 |
1820 |
1600 |
| 1 x 5 |
2100 |
2030 |
1960 |
1880 |
1750 |
1550 |
| 1 x 6 |
2025 |
1950 |
1890 |
1810 |
1680 |
1500 |
| 1 x 7 |
1950 |
1890 |
1820 |
1750 |
1630 |
1440 |
| 1 x 8 |
1875 |
1820 |
1750 |
1680 |
1560 |
1390 |
| 1 x 9 |
1800 |
1740 |
1680 |
1620 |
1510 |
1340 |
| All Gauges Hydrostatic Tested: 1.5 times 100 °F Rating |
|
| |
|
| |
Pressure and Temperature Ratings:
ARCHON Reflex Gauges Model TL |
| |
| Size Gauge |
100 ° F |
200 ° F |
300 ° F |
400 ° F |
500 ° F |
600 ° F |
| 1 x 1 |
2000 |
1930 |
1870 |
1790 |
1660 |
1480 |
| 1 x 2 |
1815 |
1715 |
1690 |
1620 |
1510 |
1340 |
| 1 x 3 |
1630 |
1580 |
1520 |
1460 |
1360 |
1210 |
| 1 x 4 |
1440 |
1390 |
1340 |
1290 |
1200 |
1060 |
| 1 x 5 |
1250 |
1210 |
1170 |
1120 |
1040 |
920 |
| 1 x 6 |
1065 |
1030 |
995 |
950 |
890 |
790 |
| 1 x 7 |
875 |
845 |
815 |
785 |
730 |
645 |
| 1 x 8 |
690 |
665 |
645 |
620 |
575 |
510 |
| 1 x 9 |
500 |
480 |
465 |
445 |
415 |
370 |
| All Gauges Hydrostatic Tested: 1.5 times 100 °F Rating |
|
| |
|
| |
Correction Factor Table-To be Applied to the 100% Ratings Listed Above |
| |
| % of Rating |
100% |
75% |
50% |
25% |
| Chamber |
Carbon Steel, 304SS and 316SS |
Monel |
Bronze |
|
| Gasket Material Liquid Side: |
Teflon Lo-Flo, Non-Asbestos |
|
Pure Teflon Kel-F Shields |
|
| Gasket Material Liquid & Cover Side |
Non-Asbestos |
|
Teflon Lo-Flo |
Pure Teflon |
| Optional Features |
Non-Frost Extensions
(Max. Temp. 100 °F ) |
|
|
|
|
| |
|
| |
|
|
| |
|
| |
|
|