Pressure and Temperature Ratings:
ARCHON Reflex Gauges Model RLC |
| |
| Size Gauge |
100 ° F |
200 ° F |
300 ° F |
400 ° F |
500 ° F |
600 ° F |
| 1 x 1 |
2000 |
1900 |
1850 |
1750 |
1550 |
1300 |
| 1 x 2 |
1950 |
1850 |
1750 |
1600 |
1450 |
1270 |
| 1 x 3 |
1900 |
1800 |
1700 |
1550 |
1400 |
1250 |
| 1 x 4 |
1850 |
1750 |
1650 |
1500 |
1350 |
1220 |
| 1 x 5 |
1800 |
1700 |
1600 |
1450 |
1300 |
1200 |
| 1 x 6 |
1750 |
1650 |
1550 |
1400 |
1250 |
1170 |
| 1 x 7 |
1700 |
1600 |
1500 |
1350 |
1200 |
1150 |
| 1 x 8 |
1600 |
1500 |
1400 |
1300 |
1150 |
1100 |
| 1 x 9 |
1500 |
1400 |
1350 |
1250 |
1100 |
1050 |
| |
|
| |
|
| |
Pressure and Temperature Ratings:
ARCHON Reflex Gauges Model TLC |
| |
| Size Gauge |
100 °F |
200 °F |
300 °F |
400 °F |
500 °F |
600 °F |
| 1 x 1 |
1500 |
1400 |
1300 |
1150 |
1000 |
850 |
| 1 x 2 |
1450 |
1350 |
1250 |
1100 |
970 |
830 |
| 1 x 3 |
1400 |
1300 |
1200 |
1070 |
940 |
800 |
| 1 x 4 |
1350 |
1250 |
1150 |
1040 |
900 |
770 |
| 1 x 5 |
1300 |
1200 |
1100 |
1000 |
870 |
750 |
| 1 x 6 |
1250 |
1150 |
1050 |
950 |
830 |
720 |
| 1 x 7 |
1200 |
1100 |
1000 |
900 |
800 |
700 |
| 1 x 8 |
1100 |
1050 |
950 |
850 |
750 |
650 |
| 1 x 9 |
1000 |
950 |
850 |
750 |
650 |
550 |
| |
|
| |
|
| |
Correction Factor Table-To be Applied to the 100% Ratings Listed Above |
| |
| % of Rating |
100% |
75% |
50% |
25% |
| Chamber |
Carbon Steel, 304SS and 316SS |
Monel |
Bronze |
|
| Gasket Material Liquid Side: |
Teflon Lo-Flo, Non-Asbestos |
|
Pure Teflon Kel-F Shields |
|
| Gasket Material Liquid & Cover Side |
Non-Asbestos |
|
Teflon Lo-Flo |
Pure Teflon |
| Optional Features |
Non-Frost Extensions
(Max. Temp. 100 °F ) |
|
|
|
|
| |
|
| |
|
|
| |
|
| |
|
|