Pressure and Temperature Ratings:
ARCHON Reflex Gauges Model RH |
| |
| Size Gauge |
100 ° F |
200 ° F |
300 ° F |
400 ° F |
500 ° F |
600 ° F |
1 x 1 |
4000 |
3800 |
3600 |
3350 |
3100 |
2775 |
1 x 2 |
3850 |
3700 |
3500 |
3200 |
2950 |
2650 |
1 x 3 |
3700 |
3500 |
3300 |
3100 |
2850 |
2550 |
1 x 4 |
3600 |
3400 |
3250 |
3000 |
2750 |
2450 |
1 x 5 |
3450 |
3300 |
3100 |
2900 |
2650 |
2400 |
1 x 6 |
3300 |
3150 |
3000 |
2800 |
2550 |
2300 |
1 x 7 |
3200 |
3050 |
290 |
2700 |
2450 |
2200 |
1 x 8 |
3100 |
2950 |
2800 |
2550 |
2350 |
2100 |
1 x 9 |
3000 |
2800 |
2650 |
2450 |
2250 |
2000 |
All Gauges Hydrostatic Tested: 1.5 times 100 °F Rating |
|
| |
|
| |
Pressure and Temperature Ratings:
ARCHON Reflex Gauges Model TH |
| |
| Size Gauge |
100 ° F |
200 ° F |
300 ° F |
400 ° F |
500 ° F |
600 ° F |
| 1 x 1 |
3000 |
2850 |
2750 |
2550 |
2300 |
2000 |
| 1 x 2 |
2850 |
2700 |
2550 |
2400 |
2200 |
1900 |
| 1 x 3 |
2700 |
2550 |
2400 |
2300 |
2100 |
1800 |
| 1 x 4 |
2600 |
2450 |
2300 |
2200 |
1950 |
1750 |
| 1 x 5 |
2550 |
2300 |
2200 |
2100 |
1850 |
1600 |
| 1 x 6 |
2400 |
2250 |
2100 |
2000 |
1800 |
1500 |
| 1 x 7 |
2250 |
2100 |
1950 |
1850 |
1700 |
1450 |
| 1 x 8 |
2100 |
1950 |
1800 |
1700 |
1600 |
1350 |
| 1 x 9 |
2000 |
1900 |
1750 |
1650 |
1500 |
1300 |
| All Gauges Hydrostatic Tested: 1.5 times 100 °F Rating |
|
| |
|
| |
Correction Factor Table-To be Applied to the 100% Ratings Listed Above |
| |
| % of Rating |
100% |
75% |
50% |
25% |
| Chamber |
Carbon Steel, 304SS and 316SS |
Monel |
Bronze |
|
| Gasket Material Liquid Side: |
Teflon Lo-Flo, Non-Asbestos |
|
Pure Teflon Kel-F Shields |
|
| Gasket Material Liquid & Cover Side |
Non-Asbestos |
|
Teflon Lo-Flo |
Pure Teflon |
| Optional Features |
Non-Frost Extensions
(Max.Temp.100 °F ) |
|
|
|
|
| |
|
| |
|
|
| |
|
| |
|
|